{"id":6996,"date":"2026-11-26T14:30:19","date_gmt":"2026-11-26T06:30:19","guid":{"rendered":"https:\/\/leaditop.com\/lt111-vs-lt104-cds-vs-ir-photocell-sensors\/"},"modified":"2026-11-26T14:30:19","modified_gmt":"2026-11-26T06:30:19","slug":"lt111-vs-lt104-cds-vs-ir-photocell-sensors","status":"publish","type":"post","link":"https:\/\/leaditop.com\/nl\/lt111-vs-lt104-cds-vs-ir-photocell-sensors\/","title":{"rendered":"LT111 versus LT104: Vergelijking van CDS- en IR-sensorfotocellen"},"content":{"rendered":"<p>Here is a spec-writer&#8217;s problem. Two photocell switches can have exactly the same specifications, but they can use different sensor elements inside. The latter determines if the turn-on threshold is fixed for ten years or will drift from season to season.<\/p>\n<p>This guide provides a comparison between Lead-Top models LT111 and LT104, in which the former uses a CdS photocell lighting sensor, while the latter uses an infrared phototransistor. It also explains the phenomenon of drift, which you have probably been hearing a lot about.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/leaditop.com\/wp-content\/uploads\/2026\/11\/cds-vs-ir-photocell-sensor-comparison-banner.webp\" alt=\"Vergelijking van CdS-fotocel en IR-fotocelsensor bij schemering en nachtelijke straatverlichting.\" \/><\/p>\n<h2>What Are the Two Sensing Technologies?<\/h2>\n<ul>\n<li>CdS cell<\/li>\n<\/ul>\n<p>Photoresistive sensor whose resistance varies depending on illumination. The circuit detects the value of resistance.<\/p>\n<ul>\n<li>IR-fototransistor<\/li>\n<\/ul>\n<p>Light-emitting diode sensitive to the infrared spectrum of natural light.<\/p>\n<p>They have distinct aging behavior. There is also an architectural consideration to be mentioned here. In the Lead-Top line, CdS goes together with thermal technology, and IR goes with electronic technology.<\/p>\n<p>This is why the choice of the outdoor photocell light sensor implies the product logic as well, and hence the comparison covers whole products and not only sensors.<\/p>\n<h2>What Differences Decide the Specification?<\/h2>\n<h3>1. Photocell Sensing Technology<\/h3>\n<p>LT111, a light-dependent resistor made of cadmium sulfide, is used. In the LT104, there is an IR phototransistor. Such a difference will influence the behavior of the photocells regarding the maintenance of their sensing properties over time.<\/p>\n<h3>2. Threshold Performance Stability<\/h3>\n<p>Both models have a 10\u201316 <a href=\"https:\/\/en.wikipedia.org\/wiki\/Lux\" target=\"_blank\" rel=\"noopener\">luxe<\/a> operating range. However, due to ageing and drifting of the sensor, the CdS devices may require re-commissioning. The IR sensing technology of LT104 tends to perform more stably throughout the lifetime.<\/p>\n<h3>3. Time Delay for Switching<\/h3>\n<p>The LT111 has a 30\u2013180 second time delay. The LT104 works with a 3\u201310 second time delay. It allows faster switching because of changing light conditions and avoiding unnecessary switching because of light bursts.<\/p>\n<h3>4. Surge Protection Capability<\/h3>\n<p>The energy rating of the MOV for LT111 is not mentioned. The LT104 provides 160J surge protection.<\/p>\n<h3>5. Number of Switching Cycles<\/h3>\n<p>The number of supported switching cycles is over 5,000 for the LT111 and over 10,000 for the LT104. It is relevant when using equipment in areas where the number of switching processes causes increased wear and tear.<\/p>\n<h3>6. Low-Voltage Work<\/h3>\n<p>The lower limit of operating voltage of the LT104 is 95VAC. No lower limit for this parameter of the LT111 is indicated. Projects that experience significant fluctuations in winter voltage should check this feature prior to choosing either model.<\/p>\n<h3>7. Fail Mode and <a href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"noopener\">IP-classificatie<\/a><\/h3>\n<p>Both products provide IP66 protection, but IP67 protection is optional. The LT111 utilizes standard fail-on, while the LT104 allows for fail-on or fail-off, depending on the model version. Always verify the needed fail mode and IP rating on the product specifications sheet.<\/p>\n<h3>What Is the Difference?<\/h3>\n<p>Both products have identical 10\u201316 lux operating range. The actual difference consists in long-term stability of the threshold value: the LT111&#8217;s CdS cell may degrade over time, while the LT104&#8217;s IR cell performs consistently.<\/p>\n<h2>Why Does CdS Photo Sensor Drift?<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/leaditop.com\/wp-content\/uploads\/2026\/11\/cds-photocell-sensor-drift-elements.webp\" alt=\"Grey CdS photocells with the light-dependent resistor element visible in the window\" \/><\/p>\n<p>There are three major reasons behind most of the CdS complaints:<\/p>\n<ul>\n<li>Material aging. Sintered cadmium sulphide composition is affected by sunlight throughout years of exposure.<\/li>\n<li>Light-history effect. Previous sunny days influence current readings.<\/li>\n<li>Contamination. Dust and\/or salt film deposition on the window affects threshold sensitivity.<\/li>\n<\/ul>\n<h3>What does drift look like in the field?<\/h3>\n<p>The drift is usually reported as the seasonal problem:<\/p>\n<ul>\n<li>Lights turn on earlier every winter<\/li>\n<li>Lights remain on later every spring<\/li>\n<\/ul>\n<p>Since the problem is caused by material degradation, the only way to address the problem is replacement of the entire unit. Recalibration does not help in such a case.<\/p>\n<h3>What does drift cost a project?<\/h3>\n<p>The drift is easily overlooked during the quotation but difficult to overlook in year five. Consider the following expenses:<\/p>\n<ul>\n<li>Fleet inspection and unit replacement due to switching at wrong hours<\/li>\n<li>Customer complaints or calls from councils, residents or site managers<\/li>\n<li>Energy waste caused by premature lighting or safety risk associated with late lighting<\/li>\n<li>Commissioning time spent across fleet and not per unit<\/li>\n<\/ul>\n<p>In some cases, a cheaper unit will end up being more expensive if it will need to be replaced sooner. Always consider lifetime costs.<\/p>\n<h2>Why Does IR Photocontrols Hold Its Threshold Better?<\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/leaditop.com\/wp-content\/uploads\/2026\/11\/lt104-ir-photocell-sensor-blue.webp\" alt=\"Blue LT104 photocell with internal IR sensing circuit board shown through the housing\" \/><\/p>\n<ul>\n<li>There is no aging mechanism in a <a href=\"https:\/\/en.wikipedia.org\/wiki\/Photoresistor\" target=\"_blank\" rel=\"noopener\">fototransistor <\/a>junction, unlike the CdS cell. The turn-on band remains where the datasheet specifies.<\/li>\n<li>Its spectral sensitivity profile reflects the amount of infrared in daylight, which stabilizes dusk readings.<\/li>\n<\/ul>\n<p>This is a general trend, but there is no guarantee. The current generation of Lead-Top photocontrols lacks comparative stability test data published on the same sheet. Request the tests if this parameter becomes a dealbreaker.<\/p>\n<h3>What can you write into a tender?<\/h3>\n<p>Datasheets and tenders in the market now explicitly prohibit CdS cells as an acceptable technology. Here is how a purchaser can formulate it in a sentence:<\/p>\n<p>&quot;The photocontrol shall employ an infrared phototransistor sensing element. CdS photocells are not acceptable.&quot;<\/p>\n<p>Verify the wording against the datasheet of the product you quote.<\/p>\n<h3>Who should skip the IR route?<\/h3>\n<p>Extremely low-cost tenders, where the cost of drift is never estimated. This is a valid application case, but it should be chosen intentionally.<\/p>\n<h2>Which Sensor Belongs in Your Specification?<\/h2>\n<p>Answer these four questions:<\/p>\n<ul>\n<li>Threshold stability over the service life required by the tender?<\/li>\n<\/ul>\n<p>Yes, then IR and LT104<\/p>\n<ul>\n<li>High contamination site?<\/li>\n<\/ul>\n<p>Film contamination speeds up CdS drift; IR is safer.<\/p>\n<ul>\n<li>Re-commissioning or truck roll cost included in the job?<\/li>\n<\/ul>\n<p>Yes, drift has an associated cost, and IR wins.<\/p>\n<ul>\n<li>Budget truly precludes electronic method?<\/li>\n<\/ul>\n<p>Then LT111, accepting drift and planning for replacement.<\/p>\n<h2>Welk model past bij welk programma?<\/h2>\n<ul>\n<li>Cost-first programme, drift okay: <a href=\"https:\/\/leaditop.com\/nl\/product\/120v-goedgekeurde-fotocelsensor-fotocontrole-led-straatverlichtingsregeling-fotocontrole-foto-elektrische-sensorschakelaar\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#d63638; font-weight:600;\"><strong>LT111 Thermal Approved Photocell Sensor<\/strong><\/a><\/li>\n<li>Stability critical specification, high contamination site, fleet priced per service life: <a href=\"https:\/\/leaditop.com\/nl\/product\/fotocelda-led-straatverlichting-fotocel-sensor-lichtregeling-fotocontrole-foto-elektrische-sensor-schakelaar\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#d63638; font-weight:600;\"><strong>LT104 Fotocelda LED Streetlight Photocell Sensor<\/strong><\/a><\/li>\n<\/ul>\n<p>Consult the two products&#8217; pages, the thermal versus electronic method page, the cold weather page regarding winter drift, and the lux levels and time delays page for specification language.<\/p>\n<h2>Veelgestelde vragen<\/h2>\n<h3>Why do CdS photocells drift over time?<\/h3>\n<p>CdS photocells are light-dependent resistors made from a sintered element, the chemistry of which gets altered with years of light exposure.<\/p>\n<p>This means a drift in the turn-on threshold, evident mainly in the shift in seasons when the time at which the switch comes on becomes different. It can\u2019t be recalibrated out since it is caused by a change in the sensor chemistry. The solution, therefore, is replacing the sensor or using an IR-based one from the beginning.<\/p>\n<h3>Why do some datasheets state that CdS cells are not acceptable?<\/h3>\n<p>Since CdS sensors drift, their only promise (of stability in turn-on threshold) is broken, and so specification writers whose fleets experience drift issues with seasons will make the sensor requirement part of the tender.<\/p>\n<p>If your specification requires switching stability for over ten years, ensure you make the sensor requirement known and use IR-based models like LT104.<\/p>\n<h3>Can I replace a CdS photocell with an IR-based one on the same pole?<\/h3>\n<p>From a mechanical perspective, yes. Both LT111 and LT104 use ANSI C136.10 twist-lock, which means that there will be no need to change a luminaire. From an electrical perspective, make sure you have the same voltage version and load capacity before placing the order.<\/p>\n<p>The LT104 is designed for voltages ranging from 120 to 277 with a 2A E-Ballast rating. Regarding the behaviour, expect faster switching due to the shorter delay of about 3 to 10 seconds and non-seasonal threshold variation.<\/p>\n<h3>Which sensor type suits coastal or dusty sites?<\/h3>\n<p>The IR-type LT104. Drift in CdS is aggravated by film formation on the surfaces, and a salty environment and dust deposited on the cell window contribute to the threshold shift along with the ageing process.<\/p>\n<p>The LT104 offers the IP67 option for wash-down and salt spray-driven applications. However, the IP rating does not guarantee salt corrosion resistance, and we recommend checking the salt spray report separately.<\/p>\n<h3>What information should I send to get the right model?<\/h3>\n<p>You need to provide site conditions (coastal, dusty, road class), power voltage, and load. Then, Lead-Top will provide the sensor-matched model and sample.<\/p>\n<h2>Laatste woorden<\/h2>\n<p>LT111 and LT104 have a common lux range on paper but different time during which it lasts. In case the stability of the threshold is crucial during service life, IR-based LT104 can be considered. However, if it is too expensive due to budget constraints and slow drift is acceptable, then LT111 can still be used.<\/p>\n<p>Send <a href=\"https:\/\/leaditop.com\/nl\/contact\/\" target=\"_blank\" rel=\"noopener\" style=\"color:#d63638; font-weight:600;\">Lood-Top<\/a> site conditions, voltage, and load. The company will provide a sensor-matched model and sample in 48 hours.<\/p>\n<h2>Externe links<\/h2>\n<ul>\n<li><a href=\"https:\/\/en.wikipedia.org\/wiki\/Lux\" target=\"_blank\" rel=\"noopener\">https:\/\/en.wikipedia.org\/wiki\/Lux<\/a><\/li>\n<li><a href=\"https:\/\/www.iec.ch\/ip-ratings\" target=\"_blank\" rel=\"noopener\">https:\/\/www.iec.ch\/ip-ratings<\/a><\/li>\n<li><a href=\"https:\/\/en.wikipedia.org\/wiki\/Photoresistor\" target=\"_blank\" rel=\"noopener\">https:\/\/en.wikipedia.org\/wiki\/Photoresistor<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Here is a spec-writer&#8217;s problem. Two photocell switches can have exactly the same specifications, but they can use different sensor elements inside. The latter determines if the turn-on threshold is fixed for ten years or will drift from season to season. This guide provides a comparison between Lead-Top models LT111 and LT104, in which the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":6989,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-6996","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/posts\/6996","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/comments?post=6996"}],"version-history":[{"count":0,"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/posts\/6996\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/media\/6989"}],"wp:attachment":[{"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/media?parent=6996"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/categories?post=6996"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/leaditop.com\/nl\/wp-json\/wp\/v2\/tags?post=6996"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}